Programming software PRS 602-... Programming and management of the Siedle Variobus History 2020-05-06 PRS 602-02 V5.4.1.4 • [PRS-22] Fixed reading/writing devices on computers where previous version of the PRS was installed 2020-03-27 PRS 602-02 V5.4.1.3 • Problem with .NT 4.8 installer fixed when repairing an installation • [PRS-10] Empty DRM entries could be written to device • [PRS-11] Sort criterion display incorrect/collapsing when using Symbols • [PRS-13] FPM firmware updated needed connected EC in the project • [PRS-14] Feedback when used COM port implemented • [PRS-17] Updated DRM 612 online help with temperature warning • [PRS-19] Fix crash when trying to update the FPM Firmware • [PRS-20] Fix rare crash when navigating in the TreeView • Reworked ToolBar/TreeView for [PRS-20] • Dependencies updated • Updated to .NET 4.8 • COM/ELM firmware list updated • Disabled FreeSort for DRM 612, not supported • Missing property for FPM template now stored in project file • Description fields no accept multi line entries • Fixes for RC/RCE and RC/DIM implemented • Inverse Display (DRM 612) now available for electrician • Fixes to window order -------------------------------- 2016-03-08 PRS 602-02 V5.3.0.50 • Fixed missing character in Czech DIM programming -------------------------------- 2016-02-18 PRS 602-02 V5.3.0.4 • Fixed DRM password display in janitor mode -------------------------------- 2016-01-26 PRS 602-02 V5.3.0.3 • Added import of Excel files for DRM entries • Added SKT identification • Added detailed message when the programming of the ELM failes with an incorrect entry • Fixed import of old PRS backup using the Dutch language • Fixed problems when reading DRMs written with the old PRS (improved tolerance for invalid chars) • Fixed incorrect length when writing entries to the RC in combination with DRM • Fixed problem when importing old PRS projects containing more than 899 ELM entries. • Fixed issue with incorrect/missing system type in RC when written with a really old PRS • Fixed error when saving project file on one windows 10 pc. -------------------------------- 2015-02-06 PRS 602-02 V5.2.2.2 • Fixed problem with switched arrows (up/down) in the DRM 611. -------------------------------- 2015-02-04 PRS 602-02 V5.2.2.1 • Fixed problems while writing the service names to the DIM/RC -------------------------------- 2015-02-02 PRS 602-02 V5.2.2.0 • Fixed problems with the bell symbol when reading/writing to the DIM/RC combo • Fixed issue with max text length when writing to the DIM/RC combo • Fixed missing invalid sort criterion warning for the DIM -------------------------------- 2015-01-16 PRS 602-02 V5.2.1.4 • Allowed characters for the project data has been increased • Fixed DRM name/address when reading a DRM • Fixed incorrect PRS release date in print out • Fixed issue with normal/inverse DRM display in expert settings • Fixed issue with gaps in the finger list where it was impossible to fill these gaps with new fingers. • It is now possible to print sorted lists • The ELM card handling has been reworked, it is now closer to the handling of the ELM in the old PRS 602-1: - When reading/importing entries the gaps within the numbering will now be kept - Its possible to add a card to specific position when adding them to a project. - Card number in project now matches the number in the EC after writing the device • The door names and the drm type are now visible in the selection window when reading/writing the drms. • The FPM will restart when a firmware update has been cancelled. • The device list now displays the type of the drm (DRM 611 or DRM 612) when the device list has been read from the system. • The FPM will restart when a backup has been written to in the stand alone mode. • Added a column for the sort criterion in the list view of the DRM and DIM. • Fixed missing "New" button in the list view of the DRM 612 • Leading zero in EC password fixed. • Fixed incorrect (default) font in DRM print out. • Fixed collapsing Siedle symbols when using the bell. • Minor GUI fixes. -------------------------------- 2014-07-21 PRS 602-02 V5.2.0.5 • The configuration of the new DRM 612 is supported - with new characters • New is the possibility to write names from the BPS V2.10 into a PRS project • Now there is a feedback after writing the FPM security level in the "Tools" menu • In the PRS it is now possible to change the max. amount of cards depending on the amount of fingers • Are FPM detected with different firmware versions now the user sees a warning message • A new option under "Tools" read a standalone FPM to back up, and restore • Various error messages when you configure the FPM were corrected • When a repeated reading the same card occurs, the consecutive number appears now and a jump directly to the info is executed • In the "Diagnostic tabs" of the EC, now the amount of available fingers, cards and codes will be displayed • The possible length of the texts for the descriptions of the cards, fingers and codes has been increased • Various visual improvements in the GUI of the PRS were made • In the File menu, recently opened project files are displayed -------------------------------- 2013-11-22 PRS 602-02 V5.1.4.1 - no data loss (name/switching contact)after reading the FPM - EC time configuration - for example "EC blocking time definition": the using of BACKSPACE and DEL is possible - programming the RC without any entries is possible - caretaker without "Creating list with test data records" and "System - Setup - system type" - new menu item in "Project" for "Import project" (import old PRS projects) - new menu item in "Tools" for "Write FPM security level" (for standalone FPM) - new possibility to change the max. amount of electronic key cards - the dialogs "Read in cards from ELM" and "Read in fingerprint from FPM" new only with 2 buttons - the DIM service names uses automatically the call numbers 1000, 1001 ... - the error when the last finger template was deleted is corrected - the delay time when writing the RC/DRM was reduced from 180 ms down to 110 ms - adapted help texts - adapted dialog texts - call numbers with leading zeros are possible - EC V1.0 version identifier corrected - data for electronic key cards corrected => now it ist possible to edit data in the EC - now the RC setup is not editable by the caretaker - new project and new FPM: read in fingerprints is possible - new, reading FPM and EC together - after reading FPM code number FFFFFF => automatically writing the new code number generated from the PRS - error two master FPM corrected - error EC outputs and switches => false representation corrected - after reading device list, it is possible to select the next module for reading - device list with adress numbers for ervery module - write incorrect data in the RC corrected, now more then 50 data sets are possible - the search function has been improved - the RC has been removed from the tree - some little bugs -------------------------------- 2013-07-18 PRS 602-02 V5.0.4.00 - it is now assured that new FPM code numbers have always 6 digits - it's now possible to read FPM data from projects with the FPM code number FFFFFF - now the PRS can also use COM ports greater than 9 (2-digit numbers) - in the mask "Project data" numbers and letters can be entered in the field "Post code" - in the "Service mode" a manually modified FPM code number is now written correctly in FPM and EC -------------------------------- 2013-07-04 PRS 602-02 V5.0.3.00 - read error EC codes is corrected -------------------------------- 2013-06-06 PRS 602-02 V5.0.2.00 - now the DRM shows the alphabet -------------------------------- 2013-05-24 PRS 602-02 V5.0.1.00 - english helfile (.chm) integrated -------------------------------- 2013-05-17 PRS 602-02 V5.0.0.65 - new GUI, new structure - new helfiles and help textes - devicelist with firmware version - automatic handling of the FPM Code Number - new system requirements · PC with Microsoft® Windows XP SP3 (32 Bit), Windows Vista SP1, Windows 7, Windows 8 · 1-GHz-Prozessor or better with 32 Bit (x86) or 64 Bit (x64) · 1 GB RAM (32-Bit) or 2 GB RAM (64-Bit) · 20 MB free memory on hard disk · Microsoft Internet-Explorer V8.0 or newer or compatible for helpfiles (.chm) - new project format uses xml, the projects of the PRS V4... and V5... are not compatible, no possibility for reading old project files - one project, one project file - the quality of the finger templates is shown in percent (3%...100%) => like TCIP - 3 login modes for Caretaker, Installer and Siedle Service - Passwords · Caretaker "Facility" (DRM konfiguration) · Installer "Siedle" · Siedle Service: Password only for Siedle factory service (changing DRM parameters, changing FPM Code Number) - printing with preview - logfile for the service - possibility for resetting FPM modules (as delivered), please don't use this methode in a valid project - no support for RCC card programming - no support for VBPS - no automatic FPM firmware update